HCX controller

Availability
In stock

Standard mobile controller

The HCX is a control device, specially developed for a wide range of applications in the mobile hydraulics sector. The controller is available with customer-specific software. The PC program ConDoc enables a rapid adaptation to the individual machine data as well as a comprehensive diagnosis. The HCX hardware, which has been reliably tested in numerous mobile machines, is also available as programmable logic controller. Thus it combines the advantages of the proven hardware platform with those of free programming according to the international standard IEC 61131-3. Integrated current drivers and drivers for analogue inputs, frequency inputs and switch inputs provide for a fast programming result.

Highlights

  • Robust aluminum housing for outdoor use, equipped with a ventilation membrane and a status LED, protection category IP65, IP69K
  • Micro-controller C167CR, 20MHz with watchdog
  • 8 configurable switch inputs
  • 1 rotary frequency sensor input, pickup
  • 6 configurable analogue inputs
  • 2 configurable switch outputs
  • 4 proportional solenoid outputs
  • 1 power supply output for Namur sensors and potentiometers
  • Power supply: 8 VDC to 32 VDC
  • 1 CAN interface for communication, expansion, connection
    Use of CAN network variables via standard CAN (11 bit ID) and extended CAN (29 bit ID) for easy information exchange between two or more controllers
  • 1 RS-232 interface for communication with programming software
  • Reverse pole and overvoltage protection
  • Flexible use of inputs and outputs due to parameter setting for selected functions
  • Inputs and outputs diagnosis-capable
  • Various possibilities for monitoring inputs and outputs (e.g. recognition of cable breaks and short circuits).