Basic-Terminal human machine interface
In stock
Basic-Terminal complies with the Isobus-standard ISO 11783. As a universal terminal it is manufacturer-independent and can be used with all machines that comply with the Isobus-standard. Baisc-Terminal provides all basic functions needed to to operate Isobus machines.
Connections
Basic-Terminal has three connectors signed as A, B and C.
+Vin and -Vin serve the voltage supply. The signals marked with *) correspond to CiA 303-1 allocation.
The signals CAN_L and CAN_H are connected internally and are for looping through the CAN network. When TBC_PWR_in is put on the voltage (= +Vin), the terminal can be switched on. When switched on, the terminal delivers the distribution voltage (minus 1,2 V) with maximum 140 mA on TBC_PWR_out for the supply of the terminator networks.
Pin Signal
| 1 | CAN_L |
| 6 | -Vin *) |
| 2 | CAN_L *) |
| 7 | CAN_H *) |
| 3 | TBC_GND*) |
| 8 | TBC_PWR_out |
| 4 | CAN_H |
| 9 | +Vin |
| 5 | TBC_PWR_in |
The connector B is the second CAN interface which can be used e.g. as a J1939 interface. The connector C is an RS-232 interface with 12-V power supply on pin 4 for a GPS receiver and +5 V on pin 9 for Bluetooth.
Technical data
- Operating voltage: 10 V to 24 V
- Operating temperature: −10 °C to +70 °C
- Storage temperature: −20 °C to +70 °C
- Weight: 1,3 kg
- Measurements (L × W × H): 220 mm × 210 mm × 95 mm
- Protection class IP64 according to DIN 40050/15
- EMC according to ISO 14982 / PREN 55025 / Level 4
- ESD protection according to ISO 10605 Level 3
- Current consumption max. 0,5 A (< 5 W)
- Display VGA (320 pixel × 240 pixel) monochrome






Müller-Elektronik