ECU-Midi controller

Availability
In stock

The ECU-Midi is prepared for the use on utility vehicles and machines. The communication with a virtual terminal like Basic-Terminal, Basic-Terminal TOP or Ccomfort-Terminal runs on the standardized CAN network (ISO 11783). The electronic control unit is equipped with a 16-bit CPU-card with flash memory. Software updates and configuration files can be downloaded across CAN.

Actuators and sensors are connected to one up to three 42-pin connectors via a cable loop, which consists of corrugated tubes. Diagnostic functions are available for all in- and outputs, which are protected against short circuits to ground or operating voltage. The electronic control unit supplies the power for the sensors at the 42-pin connectors. All inputs for revolution sensors can be configured for sensors switching operating voltage or GND.

Technical data ECU-Midi

General:
CPU: 16-bit Fujitsu MB 90F345 with Flash-memory
Memory: Flash 512 KiB; RAM 20 KiB; 64 kbit I2C-Bus EEPROM
Connections: • 1 16-pin plug for power supply, CAN (J1939 or ISO 11783) and V24
• (option for cascading multiple Electronic Control Units)
• 42-pin plug for sensors and actuators
Powersupply: 10 VDC to 16 VDC or 19,2DC to 32 VDC
(optional with switching power supply for 10 V to 32 V)
Current (Power On): 350 mA (at 13,8 V without power output and power supply of external sensors)
Temperature range: −20 °C to +70 °C (according to IEC68-2-14-Nb, IEC68-2-30 and IEC68-2-14Na)
Housing: closed aluminum box, varnished aluminum top with gasket, stainless steel screws
Protection category:  IP66K (according to DIN 40050-9 1993)
Environmental test:  Vibration- and impact test according to IEC68-2
Measurements:  282 mm × 143 mm × 57 mm
Weight: 0,95 kg

 

16-pin plug • Power supply (electronic and power separate)
• CAN network according to J1939 or ISO 11783
(version with only one 16-pin connector with termination network)
• 2 revolution inputs
Second 16-pin plug Internal connection between 1st and 2nd 16-pin plug
• Power supply (electronic and power separate)
• CAN network according to J1939 or ISO 11783

 

42-pin plug

Inputs: • 25 for analog NPN- or PNP-sensors, four of these as 4 mA to 20 mA possible
Outputs: • 2 Lowside 1,7 A
• 18 Highside and/or Lowside 5,5 A
• 2 Highside 5,5 A, 2 Highside and/or Lowside 12 A