CAN in Automation (CiA)
headquarters@can.cia.org
www.can-cia.org
CAN products section CAN and J1939 Product Guide 2011 Switch to the J1939 product section CAN and J1939 Product Guide 2011
home

Peak-System Technik

www.peak-system.com

Headquarters

Peak-System Technik GmbH
Otto-Roehm-Str. 69
DE-64293 Darmstadt

Phone: +49-6151-817320
Fax: +49-6151-817329
Email: info@peak-system.com
URL: www.peak-system.com

Sales contact

Michael Maidhof

Phone: +49-6151-817322
Fax: +49-6151-817329
Email: sales@peak-system.com

France

Peak-System SARL France
23, Boulevard de l'Europe
FR-54500 Vandoeuvre-lés-Nancy

Phone: +33-38354-1520
Fax: +33-38354-1521
Email: france@peak-system.com
URL: www.peak-system.com

Great Britain

Computer Solutions Ltd.
1a New Haw Road
GB-KT15 2BZ Addlestone, SRY

Phone: +44-1932-829460
Fax: +44-1932-84003
Email: sales@computer-solutions.co.uk
URL: www.computer-solutions.co.uk

USA

Grid Connect Inc.
1841 Centre Point Circle, Suite 143
US-60563 Naperville, IL

Phone: +1-630-245-1445
Fax: +1-630-245-1717
Email: sales@gridconnect.com
URL: www.gridconnect.com

Phytec America LLC
203 Parfitt Way SW, Suite G100
US-98110 Bainbridge Island, WA

Phone: +1-206-780-9047
Fax: +1-206-780-9135
Email: info@phytec.com
URL: www.phytec.com

For further distributers worldwide, please refer to www.peak-system.com > contact > distributors

PCAN-Diag diagnostic tool

Availability
In stock

Handheld CAN network diagnostics unit

PCAN-Diag 2 is a handheld diagnostics unit with a wide range of functions to allow investigation of a CAN network, such as detection of the CAN bit-rate, bus load measurement, and termination measurement. As well as receiving CAN messages, it can transmit either individual messages or entire sequences of them.

The integrated two-channel oscilloscope enables visualization of CAN signals. Single CAN-IDs and various events can be used as triggers. The CAN frames are decoded from the analog signal, for example, to detect errors in the frame.

Incoming CAN messages can be displayed as symbols for clear and easy allocation. The PCAN symbol editor software supplied with this product enables convenient creation of the symbol files needed for this feature.

Output is through a color display with OLED technology which allows excellent readability even when there is strong ambient light. The user selects and operates the individual diagnostic functions using a push dial. As an alternative to high-speed CAN, CAN transceiver modules are also available on request for connecting to low-speed or single-wire CAN.

Specifications

  • High-speed CAN (ISO 11898-2), CAN transceiver module available on request for low-speed CAN (ISO 11898-3) or single-wire CAN (SAE J2411)
  • CAN connection is DE-9
  • Select from fixed and 8 user-defined bit-rates
  • OLED display with 320 × 240 pixel resolution
  • Power supply via batteries (4 × 1,5 V AA) or using supply unit provided (low-voltage socket on unit)
  • Management of device configuration, transmit lists, symbol files, and all recorded data (screenshots and CSV files) in projects
  • Internal memory card (min. 1 GiB) for saving projects. Can also be used as a USB mass storage device when connected to a PC
  • Operating temperature range of 0 °C to +50 °C (+32 °F to +122°F)

Overview of functions

  • Symbolic display of incoming CAN messages using symbol files, taking enums (lists of values) and multiplexers into account
  • Symbol files can be set up using the PCAN symbol editor software supplied with this product
  • Transmitting individual CAN frames or CAN frame lists
  • Measurement of CAN network load, displayed by means of time diagrams
  • Bus-load time diagrams can be saved as bitmap screenshots
  • Measurement of CAN termination for high-speed CAN, even while the system is running
  • Switchable CAN termination for the connected bus, depending on the transceiver module used
  • Voltage measurement for all pins of the CAN connector (D-Sub)

Features of the software PCAN-Diag editor for Windows, supplied with this product

  • Convenient configuration of all available device settings
  • Compilation of transmit lists
  • Configuration of up to 8 bit-rates per project
  • Device configuration, transmit lists, and associated symbol files can be saved in projects
  • Projects can be transferred to the memory card of the PCAN-Diag 2 using a USB connection

Oscilloscope functions

  • Oscilloscope with two independent measurement channels, each with a maximum sample rate of 20 MHz
  • Display of the CAN-high and the CAN-low signals as well as the difference of both signals
  • Inspection of external signals (with frequencies up to 1 MHz) with a probe via the BNC connection
  • Trigger configuration to frame start, frame end, CAN errors, or individual CAN frames based on their CAN-ID
  • External measurement devices can be triggered using the BNC connector
  • Depiction of raw CAN frames
  • Decoding of CAN frames from the recorded signal trace
  • Current view can be saved as a bitmap screenshot
  • Memory depth can be set to up to 64 kSamples
  • Recorded sample data can be saved as a CSV file
  • Extensive zoom functions
  • Time measurement with a resolution of up to 50 ns

Scope of supply

  • PCAN-Diag 2 in plastic casing
  • Configuration software PCAN-Diag Editor for Windows 7/Vista/XP (32/64-bit)
  • PCAN symbol editor for Windows 7/Vista/XP (32/64-bit)
  • Batteries (4 × 1,5 V AA)
  • Micro USB connector cable
  • Power supply unit with changeable plugs for Euro, U.S., and UK
  • Manual in PDF format

 Delivered in shockproof plastic box