CAN in Automation (CiA)
headquarters@can.cia.org
www.can-cia.org
CANopen Product Guide 2008
home

Janz Automationssysteme

www.janz.de

NMT
NMT slave,
NMT master,
LSS master
Error control
Node guarding,
Life guarding,
Heartbeat producer,
Heartbeat consumer
Boot-up
Yes
Node ID
Software switch
No. of PDO
RPDOs
512
TPDOs
512
PDO modes
Event-triggered,
Triggered by event-timer,
Remotely-requested,
Synchronous (cyclic),
Synchronous (acyclic),
Synchronous (cyclic) coupled to sync counter start value
PDO linking
Yes
PDO mapping
Variable
No. of SDO
Server
1
Client
1
Emergency message
Emergency producer,
Emergency consumer
Sync
Yes
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
LSS slave,
Ethernet gateway
Supported application layer
CiA 301 V 4.1
Supported frameworks
CiA 302, CiA 305,
CiA 309
Supported profiles
None
Certified
No

Headquarters

Janz Automationssysteme AG
Im Doerener Feld 8
DE-33100 Paderborn

Phone: +49-5251-1550-0
Fax: +49-5251-1550-190
Email: mailas@janz.de
URL: www.janz.de

Sales contact

Mr. Michael Rennerich

Phone: +49-5251-1550-0
Fax: +49-5251-1550-190
Email: michael.rennerich@janz.de

Technical contact

Mr. Stefan Althoefer

Phone: +49-5251-1550-0
Fax: +49-5251-1550-190
Email: stefan.althoefer@janz.de

China

Wind Hill Technologies, Ltd.
Mr. Jun Thomas Qui

Phone: +86-10-82894993
Fax: +86-10-82894983
Email: thomasqiu@windhill.com.cn

Italy

Vsystems s.r.l.
Mr. Vincenzo Di Cianni

Phone: +39-011-9661319
Fax: +39-011-9662368
Email: vdc@vsystems.it

Netherlands

SI Kwadraat B.V.
Mr. Kees Zagers

Phone: +31-40-2846656
Fax: +31-40-2838092
Email: kees@si-kwadraat.nl

Russia

VITAL Electronics JSC
Mr. Evgeniy Elizavetenkov

Phone: +7-812-3259792
Fax: +7-812-3259793
Email: eev@vital-ic.com

Scandinavia

Janz Scandinavia AB
Mr. Mikael Berger

Phone: +46-226-58916
Fax: +46-226-251100
Email: m.berger@janz.se

USA

Saelig Co. Inc.
Mr. Alan Lowne

Phone: +1-585-385-1750
Fax: +1-585-385-1768
Email: alan.lowne@saelig.com

CANcard interface board

Availability
In stock

Embedded CAN Interface For PCcard / PCMCIA Slots

  • Intelligent high performance CAN field bus adapter
  • Local intelligence with MC68LK332 with 16,78 MHz
  • 512 KiB SRAM, 16 bit wide (0 Wait states)
  • 128 KiB DPRAM, 16 bit wide
  • 512 KiB DP-Flash, 16 bit wide for firmware, CIS and FPGA configuration
  • 3.3V PCcard interface (according to standard 6.1)
  • 16-bit PCcard interface (PCMCIA) (Requires no IO address and 1 kB of memory address, optionally 128 KiB of memory address for un-banked access to DP-RAM. DP-Flash access is always banked)
  • Two SJA1000 CAN Controller
  • RS-232 serial interface optionally available on IO connector
  • Two I/O connector for attachment of external transceiver cables and debugging features
  • External transceiver cables with ISO/DIS 11898
  • Opto-isolation with 500 V barrier
  • Bus line termination 120 Ω, software switchable
  • 9-pin D-SUB connector (two needed for two CAN channels)
  • Power requirements +3,3 V, 250 mA
  • ICANOS firmware on-board
  • Optional CANopen firmware on-board