CAN in Automation (CiA)
headquarters@can.cia.org
www.can-cia.org
CANopen Product Guide 2008
home

Janz Automationssysteme

www.janz.de

NMT
NMT slave, NMT master, LSS master
Error control
Node guarding, Life guarding, Heartbeat producer, Heartbeat consumer
Boot-up
Yes
Node ID
Software switch
No. of PDO
RPDOs
512
TPDOs
512
PDO modes
Event-triggered, Triggered by event-timer, Remotely-requested, Synchronous (cyclic), Synchronous (acyclic), Synchronous (cyclic) coupled to sync counter start value
PDO linking
Yes
PDO mapping
Variable
No. of SDO
Server
1
Client
1
Emergency message
Emergency producer, Emergency consumer
Sync
Yes
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
LSS slave, Ethernet gateway
Supported application layer
CiA 301 V 4.1
Supported frameworks
CiA 302, CiA 305, CiA 309
Supported profiles
None
Certified
No

Headquarters

Janz Automationssysteme AG
Im Doerener Feld 8
DE-33100 Paderborn

Phone: +49-5251-1550-0
Fax: +49-5251-1550-190
Email: mailas@janz.de
URL: www.janz.de

Sales contact

Mr. Michael Rennerich

Phone: +49-5251-1550-0
Fax: +49-5251-1550-190
Email: michael.rennerich@janz.de

Technical contact

Mr. Stefan Althoefer

Phone: +49-5251-1550-0
Fax: +49-5251-1550-190
Email: stefan.althoefer@janz.de

China

Wind Hill Technologies, Ltd.
Mr. Jun Thomas Qui

Phone: +86-10-82894993
Fax: +86-10-82894983
Email: thomasqiu@windhill.com.cn

Italy

Vsystems s.r.l.
Mr. Vincenzo Di Cianni

Phone: +39-011-9661319
Fax: +39-011-9662368
Email: vdc@vsystems.it

Netherlands

SI Kwadraat B.V.
Mr. Kees Zagers

Phone: +31-40-2846656
Fax: +31-40-2838092
Email: kees@si-kwadraat.nl

Russia

VITAL Electronics JSC
Mr. Evgeniy Elizavetenkov

Phone: +7-812-3259792
Fax: +7-812-3259793
Email: eev@vital-ic.com

Scandinavia

Janz Scandinavia AB
Mr. Mikael Berger

Phone: +46-226-58916
Fax: +46-226-251100
Email: m.berger@janz.se

USA

Saelig Co. Inc.
Mr. Alan Lowne

Phone: +1-585-385-1750
Fax: +1-585-385-1768
Email: alan.lowne@saelig.com

CAN-104L+ interface board

Availability
In stock

Embedded CAN interface for 16 and 32 bit PC/104 sockets

Features

  • Non-intelligent and low cost CAN controller
  • Up to two CAN 2.0b interfaces with SJA1000 CAN controllers
  • 11-bit ID and 29-bit ID CAN specifications supported
  • ISO/DIS 11898
  • Ooptionally opto-isolated
  • Isolation barrier 500 V (optionally)
  • 9-pin D-SUB connector for each CAN interface at front panel, optionally pin header
  • On-board line termination 120 Ω enabled by software
  • Two diagnostic LEDs (green/yellow) per channel
  • 8-bit PC/104 interface, IEEE-P966 (only 16-bit CAN-104L)
  • 32-bit PCI slave only board (only 32-bit CAN-104L+)
  • 4 KiB addresses in lower 1 MiB memory space (only 16-bit CAN-104L)
  • No resources in I/O space needed (only 16-bit CAN-104L)
  • One interrupt IRQ 3 ˜ 15, user selectable via jumper (only 16-bit CAN-104L)
  • 5 V PCI interface (only 32-bit CAN-104L+)
  • 33 MHz bus clock frequency (only 32-bit CAN-104L+)
  • Power requirements +5 V (±5 %), max. 140 mA
  • Operating temperature range 0 °C to +70 °C
  • Non-operating temperature range −20 °C to +80 °C
  • Humidity 0 % to 80 %, non-condensing
  • Dimensions (w × d) 90 mm × 95 mm, in regard to specifications for PC/104 and PC/104+