CAN in Automation (CiA)
headquarters@can.cia.org
www.can-cia.org
CANopen Product Guide 2011
home

Schneider Electric

www.schneider-electric.com

NMT
NMT slave
Error control
Node guarding
Heartbeat producer
Heartbeat consumer
Boot-up
Yes
Node ID range
-
Node ID assignment
Hardware switch
CANopen bit-rates
-
Type of bit-rate adjustment
-
No. of PDO
RPDOs
4
TPDOs
4
PDO modes
Event-triggered
Triggered by event-timer
Synchronous (cyclic)
Synchronous (acyclic)
PDO linking
No
PDO mapping
Variable
Emergency message
-
Producer:
-
Consumer:
No. of SDO
Server
1
Client
1
Sync
No
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
None
Supported application layer
CiA 301 V 4.0.2
Supported frameworks
None
Supported profiles
None
Certified
Yes

Headquarters

Schneider Electric Industries SAS
35 rue Joseph Monier
CS 30323
FR-92506 Rueil Malmaison Cedex

URL: www.schneider-electric.com
URL: www.telemecanique.com

TeSys U I/O modules and starters-controllers

Availability
In stock

The TeSys U starter controller is a D. O. L. starter which performs the following functions:

  • Protection and control of single-phase or 3-phase motors:
    • Breaking function,
    • Overload and short-circuit protection,
    • Thermal overload protection and power switching,
  • Control of the application:
    • Protection function alarms, application monitoring (running time, number of faults, motor current values, ...),
    • logs (last five faults saved, together with motor parameter values).

These functions can be added by selecting control units and function modules which simply clip into the power base. The product can therefore be customized at the last moment. Setting-up accessories simplify or completely eliminate wiring between components.

The TeSys U basic starter-controller consists of a:

  • Power base, is independent of the control voltage and of the motor power. It incorporates the breaking function with a breaking capacity of 50 kA at 400 V, total coordination (continuity of service) and the switching function.
    • Two ratings are available: 0 A to 12 A and 0 A to 32 A.

    • Non-reversing (LUB) and reversing (LU2B).

  • Control units, must be selected according to the control voltage, the power of the motor to be protected and the type of protection required (Standard LUCA, Advanced LUCB, LUCC or LUCD or Multifunction LUCM.
  • CANopen communication module LUL C08.
  • Add-on contact blocks, indicate the following status of power base: ready, fault and pole status.
  • Reverser block, allows a non-reversing power base to be converted to reversing operation.
  • Limiter-disconnector LUA LB, this unit is mounted directly on the power base. It allows the breaking capacity to be increased up to 130 kA at 400 V.
  • Plug-in terminal blocks, for the replacement of products without rewiring.
  • Control circuit pre wiring system, numerous pre-wired accessories provide simple, clip-in connections (e.g. connection of reverser control terminals, ...)

Description

CANopen communication module LUL C08 allows direct connection of TeSys U starter-controllers and controllers on a CANopen network. Module C08 is of the slave type.

When used in conjunction with an LUC ···BL or LUC ·T1BL control unit, module LUL C08 provides control and command of the starter-controller and of the controller.

For local control requirements, the module is equipped with a configurable, 24 VDC, 0,5 A discrete output and two configurable discrete inputs.

The front panel of CANopen communication LUL C08 module comprises:

  • LED indicating module status
  • Fault signalling LED
  • LED indicating 24 V supply ON for outputs OA1, OA3 and LO1
  • DE-9 male connector for CANopen link
  • 24 VDC supply connection
  • Discrete input
  • Discrete output
  • Outputs for starter commands

Characteristics