www.schneider-electric.com

NMT
NMT slave
Error control
Node guarding
Heartbeat producer
Heartbeat consumer
Boot-up
Yes
Node ID range
-
Node ID assignment
Hardware switch
CANopen bit-rates
-
Type of bit-rate adjustment
-
No. of PDO
RPDOs
2
TPDOs
2
PDO modes
Event-triggered
Triggered by event-timer
Synchronous (cyclic)
Synchronous (acyclic)
PDO linking
Yes
PDO mapping
Static
Emergency message
Yes
Producer:
Yes
Consumer:
No. of SDO
Server
1
Client
No
Sync
No
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
None
Supported application layer
CiA 301 V 4.0.2
Supported frameworks
None
Supported profiles
CiA 401: CANopen device profile for generic I/O modules
Certified
Yes

Headquarters

Schneider Electric Industries SAS
35 rue Joseph Monier
CS 30323
FR-92506 Rueil Malmaison Cedex

URL: www.schneider-electric.com
URL: www.telemecanique.com

Advantys FTB IP67 monobloc I/O module

Availability
In stock

To meet the needs of machine manufacturers and users, automation system architectures are becoming decentralised, while offering performances comparable to those obtained with a centralised structure.

Advantys FTB IP67 monobloc I/O splitter boxes enable sensors and actuators to be connected in distributed automation systems using pre-assembled cables, thus reducing wiring time and costs, whilst at the same time increasing the operational availability of the installation.

These IP67 protected splitter boxes can also be used within processes or machines in harsh environments (splashing water, oil, dust, etc.). For difficult environments (welding shops etc.), a range of Advantys FTB splitter boxes with a metal housing is available.

Advantys FTB splitter boxes allow distributed connection of sensors and actuators on machines via a CANopen network. Sensors and actuators are connected by means of standard M12 connectors.

Configuration and parametering of the Advantys FTB splitter boxes is carried out using configuration files (e.g., .eds files for CANopen):

  • Either directly within the software workshop of the PLC used
  • Or by using a SyCon type configurator

Description

CANopen monobloc I/O splitter boxes FTB 1CN has the following on the front face:

  • 8 M12 female connectors for connection of sensors and actuators (2 channels per connector)
  • 8 channel status indicator lights (00 to 07)
  • 8 channel status indicator lights (10 to 17) or channel diagnostic indicator lights (00 to 07) depending on the splitter box configuration
  • 2 7/8 connectors for connecting the 24 VDC sensor and actuator power supplies: male for PWR IN, female for PWR OUT
  • 1 M12 male connector (bus IN) and one M12 female connector (bus OUT) for connection of the CANopen and DeviceNet buses
  • Access to coding and speed selection wheels
  • 2 network diagnostic LEDs
  • 2 × 24 VDC sensor and actuator supply status LEDs
  • 8 channel marker labels
  • 2 splitter box marker label
  • Splitter box functional earth connection (beneath the label)

Characteristics