CAN in Automation (CiA)
headquarters@can.cia.org
www.can-cia.org
CANopen Product Guide 2011
home

Telemecanique

www.telemecanique.com

NMT
NMT slave
Error control
Node guarding
Heartbeat producer
Heartbeat consumer
Boot-up
Yes
Node ID range
-
Node ID assignment
Software switch
CANopen bit-rates
-
Type of bit-rate adjustment
-
No. of PDO
RPDOs
3
TPDOs
3
PDO modes
Event-triggered
Triggered by event-timer
Remotely-requested
Synchronous (cyclic)
Synchronous (acyclic)
PDO linking
Yes
PDO mapping
Variable
Emergency message
-
Producer:
-
Consumer:
No. of SDO
Server
1
Client
No
Sync
No
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
None
Supported application layer
CiA 301 V 4.0.2
Supported frameworks
None
Supported profiles
CiA 402: CANopen device profile for drives and motion control
Certified
No

Headquarters

Schneider Electric Industries SAS
35 rue Joseph Monier
CS 30323
FR-92506 Rueil Malmaison Cedex

URL: www.schneider-electric.com
URL: www.telemecanique.com

Altivar 71 frequency inverter

Availability
In stock

Frequency inverters for 3-phase asynchronous motors from 0,37 kW to 500 kW

Simply smart benefits

Unique range up to 500 kW, exceptional performance, advanced functions...
Open to all industrial communication networks and featuring numerous automation system options, the Altivar 71 adapts effortlessly to complex sophisticated machines. Its performance levels and ease of parameter setting make it the reference product up to 500 kW.

It supports an embedded CANopen port.

Applications

High performance applications (constant torque):

  • Material handling
  • Hoisting
  • Process machines
  • Textile machines
  • Packaging
  • ...

Range description

200 V to 240 V single-phase
3-phase
50/60 Hz

  • Type of assembly: heatsink (IP21)
  • Graphic terminal: plain text, navigation button, configurable function keys, "Simply Start" menu ...
  • Integrated class0 A EMC filter, class0 B optional
  • Integrated DC choke
  • Speed regulation by flux vector control with or without sensor
  • Speed range : from 1 to 1 000 in closed loop mode with encoder feedback, from 1 to 100 in open loop mode
  • Thermal protection of motor and of drive
  • "Power Removal " safety function
  • Integrated I/O: 6 logical inputs, 2 relay outputs, 2 analog inputs, 1 analog output
  • I/O extension cards
  • interface cards for encoder
  • Integrated Modbus and CANopen
  • Network cards: Ethernet, Modbus, Uni-Telway, Fipio, Modbus Plus, Profibus DP, DeviceNet, Interbus
  • "Controller Inside" card for integrating automation functions (Programmable card ...)
  • More than 150 functions available : PID regulator, brake control suited to travelling, hoisting and slewing movements...
  • Commissioning software "PowerSuite" for PC