PCAN-Explorer 5 analyzer and diagnostic tool
In stock
Comprehensive CAN monitor for Windows 7/Vista/XP (32/64-bit)
PCAN-Explorer is a universal tool for monitoring data traffic on a CAN network. For easy and clear allocation of the individual messages, these can be identified as so-called symbols. The integrated VB-Script support allows the creation of macros to automate complex tasks. The integrated data logger means that the data traffic of a bus can be recorded, analyzed, and stored. PCAN-Explorer is designed as automation server and can therefore be remote controlled through scripts.
Features
- All files and elements can be managed and saved in projects
- Project components such as CAN connections, symbol files and macros are clearly displayed and laid out in the project browser
- The new start page allows fast access to the most recently opened projects or files
- Simultaneous connections with up to 16 networks/CAN interfaces of the same hardware type
- Connection window with an overview of all connections, complete with status, error counters, bus load, etc.
- All parameters of all elements in the user interface can be examined using a property window and edited if necessary
- Multiple flexible filters can be configured and, for example, assigned to the transmit/receive window or the various different tracers
- Tabs to switch between the different windows
- Flexible arrangement of the user interface using the dockable windows
- User-defined column display and arrangement in transmit/receive window
- J1939-support with the relevant add-in
- Display of received messages showing the ID, length, data bytes, number of messages received and receiving interval
- Simultaneous hexadecimal and symbolic representation of the details
- Display of remote frames, status reports of the CAN controller and, as option, CAN network error frames also
- Logging of time-outs
- Sending of messages at fixed intervals of time, manually or as reply to remote frames
- Messages can be created as send lists, stored and loaded as desired, in order to e.g., emulate CAN nodes
- Periodical sending with up to 1 ms precision
- Easy creation of symbol files and macros using the integrated text editor with syntax highlighting
- User-friendly real-time monitoring of several signals via the watch window
- Extensive improvements to user guidance and interface compared to PCAN-Explorer version 4
- User interface language can be switched (German/English)
- Simple integration of external tools
- Integration of add-ins to upgrade functionality
Properties of the integrated, configurable PCAN-Explorer data logger
- Operation of multiple tracers at the same time
- Variable buffer size
- Optional linear buffer or circular buffer
- Representation of the logged messages with time stamp, type, ID, length and data bytes
- Logging of errors that have occurred is possible
- Flexible storage possibility for the logged data in text form for importing into Excel or similar
- Filtering of the messages for logging through symbol definitions
- Subsequent examination of the logged data in the buffer via different symbol files
Function upgrade of the PCAN-Explorer with the integrated VB-Script language
- Creation of macros in VB-Script with the integrated text editor
- Access with macros and scripts to almost all program elements via the PCAN-Explorer object model
- Ideal for creating test tools to implement or develop CAN systems
- Examples
- Sending of e-mails when a temperature is exceeded
- Starting of a test tool when a particular message is received
- Opening of an Excel sheet when an event occurs and saving of data in the individual cells
- Assignment of function keys with individual send messages or macros
- VBS scripts run in the background even without the PCAN-Explorer interface
Properties of the independent PCAN symbol editor
- Symbolic representation of CAN messages through the assigning of alphanumeric names
- Bit-exact division of the data into variables for assigning name, data type, list of values, scaling, offset etc.
- Supports data processing in accordance with IEEE 754 as well as in the Intel and Motorola format
- Set up user-defined outputs using lists of values (Enums)
- Use of multiplexers for outputting CAN data of a single CAN-ID with different symbol definitions
- The graphic representation of symbols and the automatic error detection allow easy creation of symbol files
- The item navigator and the search function allow targeted access to all elements of the symbol files
- Creation of virtual variables for CAN-independent inputs and outputs and macro calculations (in conjunction with PCAN-Explorer only)
- Importing of CANdb files into the symbol data format and vice versa (requires the PCAN-Explorer add-in CANdb Import)
- Supports symbols for J1939 message formats (requires the PCAN-Explorer add-in J1939)
The J1939 add-in for PCAN-Explorer 5
The J1939 add-in for PCAN-Explorer 5 supports all definitions established by the standard's parameter groups and provides a simple means of accessing the parameters. A complete database of all the definitions and the parameters contained is also supplied.
Features
- Support of all functions of the SAE J1939 network protocol
- CAN messages can be sent in broadcast form or targeted to individual control units (ECUs)
- Addressing of up to 254 ECUs
- Supports multi-packet messages
Scope of supply
- PCAN-Explorer installation CD including PCAN-Explorer line writer add-in
- PCAN Symbol Editor for Windows 7/Vista/XP (32/64-bit)
- Documentation in HTML help format
Optional
- J1939 add-in
- Plotter add-in
- CANdb import add-in
- Instruments panel add-in




Peak-System Technik